In some cases, for instance when a cell phone is lost, components cannot be removed via the standard method. In that situation, components can be factory restored via the Maintenence mode.

\uD83D\uDCD8 Instruction

Procedure is done by turning ON and OFF luminaire’s power supply according to instruction below.

Instruction

The luminaires must be powered ON for more than 15 seconds.

  • Power OFF mains for more than 10 seconds but less than 15 seconds (disconnect device form mains)

  • Power ON mains for 2 to 3 seconds (reconnect device to mains)

  • Repeat above process for 4 times

  • On the 5th cycle, leave the fixtures powered ON at the end. You should see a short dim-down/dim-up signal. Sensors are now in Maintenance mode.

  • Scan with “Device Maintenance” to discover the sensors that are now In Safe Mode and Reset them, see screenshots below:

Info

Highlight important information in a panel like this one. To edit this panel's color or style, select one of the options in the menu.

Filter by label (Content by label)showLabelsfalsemax5spacescom.atlassian.confluence.content.render.xhtml.model.resource.identifiers.SpaceResourceIdentifier@1156asortmodifiedshowSpacefalsereversetruetypepagecqllabel = "kb-how-to-article" and type = "page" and space = "GWZ"labelskb-how-to-article