Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Project report

Project reports are available from the Project window top menu bar.

Report types

Room assembly list luminaires

The assembly list shows the set of luminaires used in each room, with information such as gear, load and effect.

Room List light sources

This is a list of rooms and the light sources used in this room, with the total count for each type.

Assembly List Luminaires

The assembly list shows a summary of all luminaires used in the selected set of rooms, with their gear and count.

A pictures of each luminaire can be included in the list by checking the "Picture" option.

Assembly List light sources

This assembly list shows a summary of all light sources used in the selected set of rooms, with a total count.

Neutral printout

Checking this option will remove the Glamox logo from the reports.

Calculated result

The calculated result option is used to create a series of room reports into a single report document.

When the calculated result-option is checked, only rooms which has luminares placed from the luminaire placement window will be listed.

Select a set of rooms and click Report will take you to the room report window, where you can set up the common properties for all rooms.

Note: rooms without calculated results will be shown with a star (*) marking behind the name

Room/Product Matrix

Creates a table overview of rooms and luminaires/LMS.

Room report

Room reports are available from the Room window top menu bar, or through the "Calculated result" option for Project reports.

Basic summary

To create a basic summary you just have to press the "Report" button once inside the report window.

The basic summary includes room characteristics, calculation results, luminaire data and an ISOLux-diagram for the room calculation plane.

Custom report

Checking the option "Define your own report" will enable all the options in this window:

The upper section contains various report parts that can be included or excluded.

The middle section contains various room objects that can be included/excluded.

The lower section contains some global options for the report.

Note: to include emergency calculations for a custom report, the "emergency light" option must be checked for the room calculation area.

Summary

This is the basic summary page, and must always be included.

Coordinate list

Check this option to include a coordinate list and an overview of the room with numbered luminaires.

3D Drawing

Check this option to include a 3D drawing of the room (isometric view).

Luminaire info

Check this option to include detailed luminaire information for all luminaires used in the room.

Maintenance plan

Checking this option will include page with maintenance instructions for rooms planned with the advanced maintenance factor.

Scene definitions

Check this option to include all active scene definitions for the room.

Display Calc.Points, ...

These are the display options used for calculation results in the report. The default values are the room calculation plane options.

General - Drawing background

Check this option to include the 2D/3D model background data in reports.

General - Absolute coordinates

Check this option to include the CAD import origin in the coordinate list.

General - Neutral printout

Checking this option will remove the Glamox logo from the reports.

Energy evaluation report

The energy evaluation report is available from the energy evaluation window.

The report shows a summary for the entire project, followed by a separate evaluation for each active room.

Luminaire report

The luminaire report is available from the luminaire information window.

The report shows a picture of the luminaire, a description text and a picture of the light distribution.

  • No labels