Project report
Project reports are available from the Project window top menu bar.
Report types
Room assembly list luminaires
The assembly list shows the set of luminaires used in each room, with information such as gear, load and effect.
Room List light sources
This is a list of rooms and the light sources used in this room, with the total count for each type.
Assembly List Luminaires
The assembly list shows a summary of all luminaires used in the selected set of rooms, with their gear and count.
A pictures of each luminaire can be included in the list by checking the "Picture" option.
Assembly List light sources
This assembly list shows a summary of all light sources used in the selected set of rooms, with a total count.
Neutral printout
Checking this option will remove the Glamox logo from the reports.
Calculated result
The calculated result option is used to create a series of room reports into a single report document.
When the calculated result-option is checked, only rooms which has luminares placed from the luminaire placement window will be listed.
Select a set of rooms and click Report will take you to the room report window, where you can set up the common properties for all rooms.
Note: rooms without calculated results will be shown with a star (*) marking behind the name
Room/Product Matrix
Creates a table overview of rooms and luminaires/LMS.
Room report
Room reports are available from the Room window top menu bar, or through the "Calculated result" option for Project reports.
Basic summary
To create a basic summary you just have to press the "Report" button once inside the report window.
The basic summary includes room characteristics, calculation results, luminaire data and an ISOLux-diagram for the room calculation plane.
Custom report
Checking the option "Define your own report" will enable all the options in this window:
...
The upper section contains various report parts that can be included or excluded.
The middle section contains various room objects that can be included/excluded.
The lower section contains some global options for the report.
Note: to include emergency calculations for a custom report, the "emergency light" option must be checked for the room calculation area.
Summary
This is the basic summary page, and must always be included.
Coordinate list
Check this option to include a coordinate list and an overview of the room with numbered luminaires.
3D Drawing
Check this option to include a 3D drawing of the room (isometric view).
Luminaire info
Check this option to include detailed luminaire information for all luminaires used in the room.
Maintenance plan
Checking this option will include page with maintenance instructions for rooms planned with the advanced maintenance factor.
Scene definitions
Check this option to include all active scene definitions for the room.
Display Calc.Points, ...
These are the display options used for calculation results in the report. The default values are the room calculation plane options.
General - Drawing background
Check this option to include the 2D/3D model background data in reports.
General - Absolute coordinates
Check this option to include the CAD import origin in the coordinate list.
General - Neutral printout
Checking this option will remove the Glamox logo from the reports.
Energy evaluation report
The energy evaluation report is available from the energy evaluation window.
The report shows a summary for the entire project, followed by a separate evaluation for each active room.
Luminaire report
The luminaire report is available from the luminaire information window.
The report shows a picture of the luminaire, a description text and a picture of the light distribution.